HAZARDOUS AREA SENSORS

HAZARDOUS AREA SENSORS

UKEX / ATEX / IECEx explosion proof
Robust and weatherproof
3 alarm points (see relay option)
Addressable or stand alone
CANbus, 4-20mA outputs
Wide range of gas types/sensors
Data logging
Options: 3 selectable alarm relays
Options: Cable entry 25mm, 3/4 NPT
Wide range of accessories
Inquire Now

The XDI-F1+ Gas Sensor is capable of utilising a wide range of sensor cell types offering an unmatched number of gases that may be monitored. Standard 4-20mA signaling with CANbus address enables the sensors to be networked via the GDS Combi control system or customer preferred monitoring systems.

CERTIFICATION

  • Explosion Proof UKEX (C1971) ATEX (C1969) IECEx (C1970) II 2GD
  • Ex db IIC T6...T4 Gb
  • Ex tb IIIC T85°C...T135°C Db
  • Ta = -20˚C ≤ Ta ≤+35°C... +75°C (XDIwin +F1, F1+ and F1+S)
  • Ta = -20˚C ≤ Ta ≤+35°C... +85°C (XDI +F1, F1+ and F1+S)

POWER SUPPLY

  • 18 to 30vDC 24v nominal
  • Power consumption – 4W full alarm

Outputs

  • 3 wire – 4~20mA sink/source (Direct)
  • 4 wire – CANbus (Addressable)

Logging

  • Intervals – variable time
  • Roll over/stop
  • Storage – 2,880 readings

Relays (optional)

  • 1, 2, 3 Individual alarm relay selection
  • Low, High, Overrange, Fault
  • Default setting:
  • 1 -Low Alarm
  • 2 -High Alarm
  • 3 -Fault Alarm
  • Rating 3A (non inductive) @30vDC S.P.C.O
  • Inhibit option during servicing
  • Delay to activate 0~255s
  • Relay off delay 0~255s
Relays (optional) image 1

Sensor Inserts – 4 series

  • Infrared, Electrochemical,
  • Catalytic, Semiconductor, PID

Measuring Range

  • Flammable gases – LEL / % vol
  • Toxic gases – ppm/ppb
  • Oxygen % vol, depletion/enrichment

Three Relay PCB – Option

    Three Relay PCB – Option image 1

    HOUSING MATERIAL

    • Copper free aluminium alloy, optional stainless steel

    Finish

    • Chemical resistant epoxy paint RAL 9003 – Signal White
    • Marine grade finish
    • F1 sensor material – Stainless Steel 316

    Ingress Protection

    • IP64 + water shield IP65 with hydrophobic screen IP66

    Cable Entry

    • 2 x M20 – 1.5 pitch – alternatives 25mm – 3/4 NPT

    Weight

    • 1.6kg

    Temperature

    • –15˚C to +55˚C
    • For hazardous area use see temperature ranges (certification)

    Humidity

    • 5 to 95% RH non–condensing

    Transmitter Technical Data

    • Documents:
    • Flammable – C1883
    • Toxic/Oxygen– C1882

    Accessories See F1+ data sheet C1901

    • 003–010 Collector Cone & Universal Fitting (1)
    • 003–020 Universal fitting (Test Gas Applicator/ Spray Deflector) (2)
    • 008–311 Flow Block – nylatron (3)
    • 008–310 Flow Block – stainless steel (3)
    • 003–035 Water Shield – stainless steel (4)
    • 003–090 Duct Mount Kit
    • 003–083 Detector Head Weather Shield
    • 003–130 Thermal Jacket
    • 003–070 Ceiling Mount Bracket