GASVAC SOLO PLUS

GASVAC SOLO PLUS

Low cost, high reliability
Monitor up to 4 gas types
1~8 sample lines
Switch selectable, sample, purge and drain times
Peristaltic drain pump as standard
Easily installed
Low maintenance requirement
Line blockage and pump fail monitoring
CAN status indicator for internal or remote gas readouts C1829 (option)
Cabinet gas monitoring with auto shutdown (option)
Patented micropore sampling for multi-point mixed lighter and heavier than air gases (MPS option) C1814
Hazardous area sampling (option)
Data link – full remote monitoring C1550 (option)
Inquire Now

Multi-function multi-application multi line flow sample system, continuously monitoring up to 4 gas types from the harshest of environments. The GasVac® Solo+ has a unique system controller which enables three main functions to be selected according to site conditions and sampling requirements: sampling time, clean air purge time and condensate drain cycle time. The GasVac® Solo+ offers low cost, high reliability with proven technology, the complete package for any application.

Sensors

  • 1~4
  • Infrared, Electrochemical, PID
  • Covering over 700 gas types

Measurements

  • Combustible Gas – LEL / % Vol
  • Toxic gas – ppm / % Vol
  • Oxygen – % Vol. depletion / enrichment
  • Refrigerant – ppm
  • Any 4~20mA source input signal

Power Supply

  • 230/115v AC/24v DC

Outputs

  • Sample 1~8 line indication 4~20mA (2mA increments)
  • Gas level readings 4~20mA / CANbus
  • Pump fail line blockage S.P.C.O
  • Individual sensor alarm relays (optional)
  • Low / High / Over-range – Fault S.P.C.O
  • Cabinet sensor – S.P.C.O (optional)
  • Supply fail – S.P.C.O (optional)

Selectable Drain Cycles

  • 1, 2, 4, 8

  • A sample is extracted from the target area for a timed period during which gas readings are taken at 5 second intervals.
  • Following a full sample line cycle a selected purge period flushes the gas path with clean air, rejuvenating the sensor cells while drying out any moisture produced within the system components.
  • Moisture produced and drawn along the sample line is removed by the peristaltic pump during the selected drain cycle which corresponds with the chosen purge period.

Application

  • Biogas Recovery & Processing
  • Bio Fuel Storage
  • Odour Monitoring
  • Water Treatment
  • Tank Farm Monitoring – Storage
  • Waste Storage
  • Composting
  • Air Quality
  • Abattoirs
  • Air Conditioning Plant
  • Battery Rooms
  • Bore Holes
  • Breweries & Distilleries
  • Chilled Water Plants
  • Chiller Plant Rooms
  • Clean Rooms
  • Cold Stores
  • Distribution Centres
  • Farming & Agricultural
  • Food – Mixed Waste
  • Food Manufacture, Processing & Packaging
  • Gas flaring
  • Horticulture
  • Hospital Operating Theatres
  • Hotel Accommodation
  • Inaccessible Target Areas
  • Incubation
  • IT Server Farms
  • Landfill Perimeter
  • Marine
  • Provisions Stores
  • Refrigerant Leak Detection – Retail, Machinery

Internal Main PCB Indicators

  • Power, Purge, Sampling, Drain ON

General

  • Sample line size 6mm OD 4mm ID – push fit
  • Maximum length ASU-1 50m
  • Maximum length ASU-2 100m
  • Sample line, Nylon, PTFE, Polypropylene

Specials

  • Storage tank – full perimeter cover
  • Long line monitoring 500m
  • Large area monitoring

Enclosure

  • Sheet steel 1.5mm
  • IP66 NEMA 4
  • Base gland plate

Dimensions

  • 600mm (W) x 600mm (H) x 210mm (D)

Finish

  • RAL 7035 textured powder coat

Weight

  • 25kg

Selectable Purge/Sample Times

  • 1, 2, 4, 8, 16, 32, 64, 128 minutes
Selectable Purge/Sample Times image 1

Sample line and gas reading 4-20mA signal outputs

  • Following a sample line gas reading (No 4) the line number mA reference and mA gas value would require to be recorded and latched as required by the end user. Subsequent line ssampling will clear previous readings.
Sample line and gas reading 4-20mA signal outputs image 1